Royrey: This is not true, if you went through the correct steps, i made my payment tru online bank transfer-access bank..and within 4hrs, i was able to proceed with scheduling an appointment 1 Like |
![]() |
KingsDecorppro: what material is this?..ceramic tile, wood , PVC laminate? |
![]() |
Intellab: Your bms wasnt set up properly...the battery capacity is on default 40ah, where as it shud be 314ah . Another way is to do a capacity test.charge full .then drain and see how many ah you get from it. 3rd option is to open the case and eyeball each cell. However this may void ur warranty and isnt 100% accurate. The capacity test is the preferred option 3 Likes |
![]() |
HeavenlyBang: Most EVs use lithium ion cells, not lifepo4. Lithium ion is more energy dense and some can handle 20C and higher...while most lifepo4 is max 1c or 2c at most...as going higher than this couldead to premature battery failure... Specially designed lifepo4 may be able to handle higher C ratings...but the prismatic cells normally used for home energy storage cant 2 Likes |
![]() |
oliverjiad: Strange and sad the full and compromise duty difference is quite massive on the 2021 ford, i wonder why, do you know?. Any idea if the 2020 ford explorer full clearing is more pocket friendly? |
![]() |
Pls what is clearing cost for 1. 2016 toyota rav4 suv 2. 2021 ford explorer suv Roro shipping. Pls give me compromise and full clearing cost |
![]() |
Anyone knows the other name of umidigi note 100A, saw it 110usd on amazon, 8gb/256gb. Is it a good price...searched on aliexpress but cudnt see it to compare Edit,; sern on aliexpress, 130usd.is it a good device at that price?.are there better options? |
![]() |
kuma007: Your installer did a poor job and set the wrong voltage on the inverter/charge controller...for flooded batts you shud set it no more than 29.4v for bulk and 27.4v float. I doubt your installer understands all this, so best u take ur destiny into ur hands and change rhe settings...or find someone technical who can help u |
![]() |
NotsonewMary: If you have scheduled a dropoff date on avits...then go to ois and schedule another dropoff date...on same date. The avits date is superior and usually what they check inside the ois office..but the security at the gate check for ois ..to avoid any wahala..simply book ois date to match ur avits...time isnt important, just date 1 Like |
![]() |
anuoluwa88: YUP CANCEL AND START AFRESH, HOWEVER WHY ARE u going the hard way...why not pay online tru bank transfer, its a lot faster 1 Like |
![]() |
canadaman18: It can be done, but its a gamble, doing it one after the other... What i wud do if i were u..get another person to as well...so u effect both changes simultaneously on different devices. 2 Likes |
![]() |
Ebereola: PLS was it master card or visa card that you used. i hv tried access bank dom/usd card and even bank of America card, both visa cards....and it didn't scale tru the BOA card even got to the top page and otp entered ok, yet failed while the access bank card cudnt even get to the otp page |
![]() |
Charisdesigns: what would this cost to build now on stable land |
![]() |
diordaves: YUP, AN AVERAGE FAMILY THAT INTENDS TO RUN 1 OR 2 ACS, BUT AN AVERAGE FAMILY WITH NO PLANS OF RUNNING ACS., just lights, fans fridge, freezer.CAN get an offgrid system for far less 2 Likes |
![]() |
diordaves: the 40m quote wasn't for a home...it was for an office complex or so...... 2ndly no 2 homes are alike, ac is the major consumer of electricity in the average home, a design without ac and a design with 1 or 2 acs vs a design with up to 5 acs cant be the same. therein lies the physics...doing a proper load calculation vis a vis balancing the solar s with the battery...if for example a home consumes 20kwh daily,...a good design should hv a battery at least 1.5x this....then solar s bringing in x2 of this ...if you want a functional, no stories design...a smart installer and client can still tweak with certain aspects of the design to achieve this with smaller budget....but what happens is..a quack installer will just say buy 4 batteries, and 8 s, it will work, without doing any load calculation. an acquaintance approached me for a solar job, had fridge.freezer, sumo, 1.5hp ac....totally offgrid, I gave 2 designs, with the least about 4m+ which included a 12kwh lithium battery...the person ran away and went with another installer that gave a quote of 2m+..which included just 4 units of 200ah flooded battery. this quack installer design will fail within 6months...and the owner will now start shouting that solar doesn't work.blah blah blah....when they engaged quacks .in a bid to save money 3 Likes 2 Shares |
![]() |
visaclick: FUNNY ENOUGH, THE TIKTOK VIDEO GUY IS CORRECT. i also build/assemble lithium battery packs in my spare time, and its not rocket science, and yes lithium battery can power large loads such as sumo, ac, electric stove, microwave etc...without any damage to the battery, unlike flooded or leadacid batteries @POSTER, it appears you are largely ignorant about solar-inverter and renewable energy matters...i suggest you make out time to keep urself informed and abreast of developments in that sector, or stick to giving opinions on topics/areas you are knowledgable in 1 Like |
![]() |
gbadexy: Go lithium battery, and forget all these stories of changing battery every 2, 3 or 4 yrs..a decent lithium battery will easily do 12 to 15yrs....no hiccups 1 Like |
![]() |
gbadexy: A decent lithium battery can easily do 12yrs...however most installer recommend tubular battery, even the few that somewhat recommend lithium battery , a gew of them sometimes run into problems as they dont understand the physics...and fail to programme the inverter to work adequately with lithium battery... Lithium battery is the game changer in solar installations 1 Like |
![]() |
dapotemi: solar works, however being unregulated, too many quacks jumped into it in nigeria, who have no idea of the physics behind solar/inverter, thus ruining the experience for many people.... here is a thread where we discuss solar DIY ish. ----- https://nairaland.unblockandhide.com/390522/solar-energy-complement-fta/1897 also a link of a member who has powered an 80 room hotel with solar, and even a church headquarters... https://www.youtube.com/watch?v=7g1lyp8y28A i would advice you to engage a reputable hand or post the system design of your proposed installer on the solarforum page so we can anlyse&critique it. a good solar setup is expensive, but pays for itself after 2 to 3 yrs, depending on the size, and what is the norm in nigeria is for the client to collect quotes from 2 to 5 vendors...and then settle for the cheapest quote without understanding the nuances behind the quote 1 Like |
![]() |
Kossyfelicia: it could be possible, if she started filling the form in dec. what smart people do is to use the ds160 form number to try n book appointment, even though they hvnt finished filling the form as the form number doesn't change. if you doubt, simply ask the agent to send you a screenshot of the appointment naah, 1 Like |
![]() |
anybody booked recently?.pls whats the earliest date for abuja?. the avits people hv frustrated me since October, with my old gt bank payment and rescheduling a missed appointment, (no valid receipt found for this application error) am seriously considering making a fresh payment so I can move on....ayam absofuckinglutely tired ![]() |
![]() |
Drgreatone: TO save such back and forth..best to request for the codes b4 purchase...its very risky moving s upandan...what if 1 0r 2 broke in transit? 2 Likes |
![]() |
Urgent1Million: Hahahahahah...2000 deg C indeed...and the clipper doesnt melt. Do you know i can also put that lighter fire on my finger for few seconds..same as they do on the clipper..and nothing will happen to my finger... The inflammable liquid they douse on the clipper has a better chance of killing microbes than that fire of 3 to 10secs Its not everything we be shouting google upandan.u gotta use google with sense.... That u googled that lighter fire may reach temps of 2000 degrees..(wch is not even practical) doesnt translate to the clipper being exposed to that temperature..they could hv used matches or even candle fire to light up the clipper... The main point is that .The fire/flame lasting barely 6secs cant do shit to kill any serious bacteria...that we are even having this convo makes me scared of what is being taught in schools and level of scientific knowledge the avg nigerian has.. 4 Likes |
![]() |
illicit: very ignorant practice....na heat dey kill bacteria...not flames...that lighter fire they use...doesn't even reach 100 deg C, the temp of boiling water...let lone 300 deg C, the temp to kill most common bacteria. 9 Likes 2 Shares |
![]() |
Peterlove11: nice....me don talk wetin science talk..if you are exceeding it routinely, me no sabi again. kudos to you...are these peaks sustained/last up to 2minutes...or they just flash and go?. whats the max instantenous, you have ever obtained?...whats the max cumulative you have harvested? that your inverter anern? |
![]() |
Peterlove11: Yeah, the science checks out ok. All s in series gives you a loss of 12%, 3257watts max possible harvest 31.2volts...avg vmp Imp...105a all in parallel is 11.8% loss Arranging all similar s in series then paralleling them would hvv given you over 70% loss....i think this was where the myth of derating to the smallest comes from ojesymsym: |
![]() |
Peterlove11: nice, surprised that the mixup is producing decent results. would wanna something scientifically, if its not too much trouble... kindly provide the following data for the 4 or 5 sizes in your string wattage 1. Vmp 2. Imp 3 Likes |
![]() |
bleexInc: Amaron quanta is a unique battery, but many dont care to understand it, and hence they damage it. It requires bulk of 13.7volts and float of 13.5volt....this is clearly written on the body....unlike normal sealed batts that require 14.5volts bulk. The dumb luminous inverter you are using doesnt hv editable charge voltage settings and outputs about 14.3volts...... Hope u see where am going 3 Likes |
![]() |
Ijeoma660: Not possible now with present known technology... Its like trying to know how many kilometers a used car tyre has been driven.. 4 Likes |
![]() |
AmakaRuby: Whats your installation plan like?..complete system fresh install or tshoot old install? What area in edo state..may have 1 or 2 peeps to reco |
![]() |
swagifted: In the village..just fridge..and lights, fans etc...then sumo once a week.totally offgrid.14kwh 48v. Even if the cycle count was triple that..say 500cycles in 3yrs....thats still 12yrs minimum before degrading to 80%...even if you assume the minimum of say 2k cycles 2 Likes |
![]() |
dollarnaira: Yeah, thats why i find it funny people putting so much emphasis on lifepo4 cycle life ..3k, 6k or 10k cycles...e no too get head. My first lifepo4 pack will hit 3yrs in oct..and has about 178 cycles....so in 30yrs..will still be less than 2k cycles...so why shud i bother my head about whether its 3k or 6k or 20k cycles ![]() Any normal lifepo4 pack will easily do 15yrs.....and am sure within 10yrs...newer technology would hv even come out...that many may consider reselling their lifepo4 pack to upgrade 3 Likes |