bayo2018: 8:33am On Dec 10, 2021 |
topsy23:i guess na to look for another person be that then lols na Lagos I Dey sir. 1 Like |
joycluv: 8:33am On Dec 10, 2021 |
Hi our great architects in the house. Please what is the best layout? Accessing the guest bedroom from the anteroom or from the living room? Secondly, should the guest bedroom be so isolated from the rest of the rooms or should there be a link between it and the rest of the rooms in the house? Thanks! 1 Like |
bayo2018: 8:42am On Dec 10, 2021 |
topsy23:He said he’s using 2.5mm for socket ,AC,cooker,water heater And that the load will be direct and the circuit will be 30Amps and it’s standing on its own sir. And also he said that it is Full conduit pipe that’s being laid there that’s the reason the cable are much sir. |
twinskenny(m): 8:46am On Dec 10, 2021 |
bayo2018: Wrong o please seek alternative opinion sir… Like @topsy23 has rightly said above 1 Like |
twinskenny(m): 8:47am On Dec 10, 2021 |
bayo2018:we are in lagos and available ![]() |
twinskenny(m): 8:50am On Dec 10, 2021 |
somehow:But things are easier back then I guess 1 Like |
michlins(m): 9:00am On Dec 10, 2021 |
twinskenny:not really sure. Nigeria has never been easy from day one. Sometimes I think it's easier now sef. Take for instance, you can get jobs from strangers via Nairaland,an opportunity that never existed then. With more people earning better than ever, opportunities have increased tremendously. Before now, building has been reserved for the elites and they build once in a while. Right now, every Tom, dick and Harry is building even if it's "kobo kobo" project 3 Likes |
topsy23(m): 9:07am On Dec 10, 2021 |
bayo2018: Don't allow road side electrician to give you wrong information . The rating of circuit breaker(MCB) or starblock as normally called by this road side technicians for each of the appliances are as follow: -10A MCB is for lighting -20A MCB is for AC(direct from DB to AC switch) -20A MCB is water heater (direct from DB to water heater switch) -30A MCB or 32A MCB is for socket( you can loop 5 or 6 socket to one MCB -32A/45A MCB is for cooker control unit. 3 Likes |
topsy23(m): 9:13am On Dec 10, 2021 |
bayo2018: The electrician is not getting it right . Protecting an appliance with 32A with wrong size of cable...hmmm each cable has their own current carrying capacity and each breaker has their own protective current as well Using 30A to protect AC it means if there is fault current somewhere and your breaker suppose to trip off, it won't and the next thing is to melt the cable since the breaker refuse to trip. 1 Like 1 Share |
Valuepaints20(m): 9:20am On Dec 10, 2021 |
Good morning sir/ma Baba ólodár yíń tí dè ó Edakú é fu wá ní ísé ó Delivery to your doorstep GET VALUE FOR YOUR MONEY
|
somehow: 9:38am On Dec 10, 2021 |
joycluv: Mine is isolated from the rest of the house and can only be assessed from the anteroom. I believe your guest should not have unhindered access to the rest of the house. |
somehow: 9:39am On Dec 10, 2021 |
twinskenny: Partly because there were fewer people for the available resources. We have more people for the dwindling resources now coupled with increased corruption /greed. |
FEGEITOK: 10:03am On Dec 10, 2021 |
topsy23: topsy23: topsy23: You dropped some gold nuggets above. Though not directed at me, I am taking down notes. Thanks. 6 Likes |
Johntemmy(m): 10:37am On Dec 10, 2021 |
Good morning...... me for your any kinds of woods, woodwork etc all at affordable prices
|
joycluv: 10:48am On Dec 10, 2021 |
somehow: Thanks @somehow. More views please.... |
bolu1986(m): 11:02am On Dec 10, 2021 |
We can still take on your project before the year ends… Speak to us Pop Wall screeding Paraphet Tv wall designs in my signature
|
EgunMogaji2: 11:52am On Dec 10, 2021 |
somehow: This is very true. I happened on some of my dads old paystubs and was shocked. Asked myself how he was able to do all that he did. But it was different times. |
EgunMogaji2: 11:53am On Dec 10, 2021 |
joycluv: Personal preference but for me off of the ante and isolated. 1 Like |
topsy23(m): 12:21pm On Dec 10, 2021 |
Quality LED recessed light LIPER product made in Call and place order. 3-5years guaranty 1 Like |
Born2conquer: 12:47pm On Dec 10, 2021 |
michlins: The compound must be big then and not the usual 300sqm or 600sqm we build on |
Born2conquer: 12:50pm On Dec 10, 2021 |
mufutau55:50years Ago, May God keep upholding all the elders in the family. 1 Like |
michlins(m): 12:51pm On Dec 10, 2021 |
Born2conquer:you no see two mighty gates and two elephants on that upscale bungalow oga mi dey build now. That's how we roll 3 Likes 1 Share |
KelvinCoaster(m): 12:52pm On Dec 10, 2021 |
michlins:I agree with your submission. It is easy to make money now, just acquire the necessary skills and meet people who need your solution. |
uncleteeh(m): 1:11pm On Dec 10, 2021 |
joycluv:Both ain't bad, it depends on choice and how the design goes. Your second Q is not quite understandable. |
bmarketing: 1:49pm On Dec 10, 2021 |
rotecch77: Interesting, how many square meters |
topsy23(m): 3:01pm On Dec 10, 2021 |
On going Conceal WC installation
|
somehow: 3:32pm On Dec 10, 2021 |
Different times truly sir. EgunMogaji2: 1 Like |
twinskenny(m): 3:51pm On Dec 10, 2021 |
We set this office at computer village: Pop done by bolu1986 Paint supplied by Gbadexy Electrical, Cctv by our able self. 3 Likes |
bolu1986(m): 4:27pm On Dec 10, 2021 |
twinskenny:thanks for the help. I appreciate it |
AngelicBeing: 4:39pm On Dec 10, 2021 |
twinskenny:Very good synergy and collaborative effort from the 3 of you, this should be the way forward on here ![]() 9 Likes |
EgunMogaji2: 4:45pm On Dec 10, 2021 |
twinskenny: Na only God go "safe" us from POP people and their mess ![]() Oga Bolu na joke oo, no vex |
rmx: 4:47pm On Dec 10, 2021 |
topsy23: You dint market this to me sha , why ![]() ![]() Placed order for importation , but you never can tell |