HeavenlyBang(m): 6:31pm On Mar 28
Mrreed:
From me.
Ganfeng 25. 6v 280ah 840k

Good stuff, man. And very affordable.

3 Likes

Penuelseun(m): 6:34pm On Mar 28
ManAdii:

You can't go wrong with TBB my guy. I'm a testimony.
Yes o, I have over 10 installations using TBB and all are working till date. The only issue is that they don't have lower priced inverters again as their smallest inverter is 3kva priced at 800k

1 Like

Penuelseun(m): 6:42pm On Mar 28
oloet:

Is the tbb a HV hybrid?
it is low frequency, 250vdc is the max voltage limit for their hybrid inverter

1 Like

Ferdiwar: 7:11pm On Mar 28
Xtra Power is selling it for 950k

swagifted:
Are you for real? 6kw for 1 million naira?

1 Like

Ferdiwar: 7:15pm On Mar 28
I learnt it's not same with the other design as those ones are still very much expensive.

Penuelseun:
lol, TBB sells 5kw for 1.2m. Planning to get it
jonescosmos(m): 7:18pm On Mar 28
Most Batteries with 8 DIP Switches when used in parallel battery config are usually configured as shown on the attached picture. If you have a single pack, all DIP Switches should be down(off).

I might be wrong though but you should try it out, no harm should be caused.

I have used this config on LBSA & WECO Batteries + Deye & Growatt Inverters

Obnoxious2001:
Please who knows how to setup this battery for communication....

I am having problems settings the dip switch with my hybrid inverter (Sako)

3 Likes

temmy59: 8:40pm On Mar 28
Hello, pls if any one can help me with this yohako 1.5kva inverter issue.

I mistakenly on the solar without changing over to solar, normally it would just sound the alarm and go off, but this time around after it went off. I on it back, then it doesn't carry any thing. It just keeps going off, if I put any load on it. No matter how small

cutefy: 9:20pm On Mar 28
Good evening gurus in the house...
I need your input on this Jinko s I saw today in a distributor shop.

They are half-cut bifacial 550w for 115k.

On inspection, the s are not wrapped in papers but I saw Jinko inscription on that black hold at the back of the s.

So, chiefs what's ur take take on this.
OgogoroFreak(m): 10:20pm On Mar 28
cutefy:
Good evening gurus in the house...
I need your input on this Jinko s I saw today in a distributor shop.

They are half-cut biphasal 550w for 115k.

On inspection, the s are not wrapped in papers but I saw Jinko inscription on that black hold at the back of the s.

So, chiefs what's ur take take on this.
probably they are used s
AinsSama: 10:35pm On Mar 28
FEGEITOK:


No, it does not include night time.

Also, in some ways there is over-estimation.

The printer does not run 24/7.

The computers can also go into standby mode when not in use.

The display units may go into standby mode, but I calculated for the worst case scenario.

If it were to be a 24/7 operation, I am sure that battery would be insufficient, but for day time loads of 8 hours + 1 hour overtime just in case, I felt it is adequate.

Your views are welcome all the same
In that case a 15Kwh battery is cool. Even a 10kwh should seve.
cutefy: 10:40pm On Mar 28
OgogoroFreak:
probably they are used s

That's my thought.

Is there any draw back with used s?
Just to know if I should ignore those s.
Bruteality1: 10:44pm On Mar 28
Good evening guys. I just purchased this 4.2kva Hybrid inverter,2 tall luminous battery 230ah below. 550x4 watts Iwin energy s. I want to know if it can power my 1hp non inverter AC very well. Thanks

AndroBlaze: 3:59am On Mar 29
Bruteality1:
Good evening guys. I just purchased this 4.2kva Hybrid inverter,2 tall luminous battery 230ah below. 550x4 watts Iwin energy s. I want to know if it can power my 1hp non inverter AC very well. Thanks

Simply put.......
Inverter size = ok
s= barely acceptable
Batteries= inadequate, below standard

At best your batteries should never go beyond pushing out 520w continuously and the most efficient 1hp "inverter" ACs are around 500-650w in my limited experience. As for non-inverter ACs, I haven't really experienced them on an inverter yet but its safe to say you'll be asking your system to push out upwards of 750w and I've not even brought up the initial draw.


At best you may be able to get an hour or two on a sunny day where your s do all the work, but without sun, your batteries by themselves would sag and suffer to deal with the stress of switching on the AC let alone running it by themselves.

In short, you should have gone with Lithium batteries if you had plans to carry this kind of heavy load.

You can buy 2 more of the same batteries if you want to improve your chances of starting up the AC but if possible I'd suggest returning them and just go and invest the money on proper lithium batteries.

7 Likes

OgogoroFreak(m): 4:40am On Mar 29
cutefy:


That's my thought.

Is there any draw back with used s?
Just to know if I should ignore those s.
Yes because you have to test the capacity to be sure
darella(m): 4:41am On Mar 29
Used Mercury 2kva inverter for sale.

Scrap sale negotiable

Cost of repairs in Arena Oshodi Lagos 30k might be less.

Price of fairly used not less than 120k


Call/WhatsApp SOLD
Serious buyers only.
Obnoxious2001(m): 4:42am On Mar 29
jonescosmos:
Most Batteries with 8 DIP Switches when used in parallel battery config are usually configured as shown on the attached picture. If you have a single pack, all DIP Switches should be down(off).

I might be wrong though but you should try it out, no harm should be caused.

I have used this config on LBSA & WECO Batteries + Deye & Growatt Inverters


Thank you so much for this.

Is there any particular weco battery model that has the 8. dip switch?

So I can the manual and look through it.

The Sako inverter has an option for weco. Though this particular battery unit comes from must
Freetech: 6:48am On Mar 29
Freetech:
Pls this is far lithium ion battery in the house

Is Sukhig battery good?

Is anyone here who have or is using it?

Lastly, how many 350w Canadian do I need to charge 24v 3.5kwh lithium ion battery


Guru in the house pls attend to my question

@ valto, adollarmania etc
Christian8880: 7:03am On Mar 29
15kwh 51.2v Sms lithium batteries available
Price #2,000,000

Call or WhatsApp me on 09116033581

jonescosmos(m): 7:06am On Mar 29
The WECO 5K3 has 8pin DIP Switch. Like I said, WECO is an OEM proprietary product which follows the ieee standard for 8pin DIP.
https://wecobatteries.com//382/5k3-lv-hv-manual/2153/manual_1-17_5k3_lv_hv_weco_english-discontinued.pdf

LBSA is a DIY Pack usually assembled in South Africa using that kind of IO on your battery pack and might hold some similarities in DIP configuration as yours.
https://ursolar.co.za/manuals/LBSA--manual.pdf

So if you could post some more detail of your battery, perhaps I can get you you a precise solution.


Obnoxious2001:


Thank you so much for this.

Is there any particular weco battery model that has the 8. dip switch?

So I can the manual and look through it.

The Sako inverter has an option for weco. Though this particular battery unit comes from must

1 Like

Valto(m): 7:24am On Mar 29
Freetech:


Guru in the house pls attend to my question

@ valto, adollarmania etc
i have not used it. u should be aware the rating stated on the sticker is allegedly inflated.

we can offer u a 24v 3.5kwh lifepo4 lithium battery , with smart bms monitoring at very good price.
fuckboys: 8:44am On Mar 29
A battery with 1.2kwh, 100ah. How bad is this battery?

Haven't even hit 50ah yet and it's at 80% dod

2 Shares

Penuelseun(m): 8:58am On Mar 29
fuckboys:
A battery with 1.2kwh, 100ah. How bad is this battery?

Haven't even hit 50ah yet and it's at 80% dod
At which battery voltage did you start the discharge?
fuckboys: 9:14am On Mar 29
Penuelseun:
At which battery voltage did you start the discharge?
13.5

Charged to 14.4 and allowed to rest. Started discharge at resting voltage of 13.5
EduTechTainMent: 9:22am On Mar 29
xtremeidea:
Hello Guys,

I have a question.

i want to add a second battery to my inverter set up in a way that I can switch between battery 1 and battery 2 at anytime. Both battery will use the same source for charging (same Solar and Grid) and I don't have a problem charging only one battery at a time.

I cant merge because both batteries are different sizes and manufacturers. And I don't want to use two inverters .

Is there a change over switch that can change the battery in use between battery 1 and battery 2, just like NEPA and Generator style?

Is this doable? how do i do this?



It is possible. Infact I currently use 2 of such similar setups. However ensure you switch off the breaker between the cc and the s b4 making the switch using regular change over we use for typical switch BTW grid supply and power generator engine.

1 Like

maklelemakukula(m): 9:51am On Mar 29
Abeg which company sells original trina solar in lagos
HeavenlyBang(m): 9:53am On Mar 29
fuckboys:
A battery with 1.2kwh, 100ah. How bad is this battery?

Haven't even hit 50ah yet and it's at 80% dod

Yikes. What battery is that?
clevermugu: 10:26am On Mar 29
HeavenlyBang:


Yikes. What battery is that?
from his recent posts, u already know wink going cheap is not always the best ..u will eventually get what you paid for cool
fuckboys: 10:47am On Mar 29
HeavenlyBang:


Yikes. What battery is that?
locally assembled battery from a guy.
OgogoroFreak(m): 11:26am On Mar 29
fuckboys:
locally assembled battery from a guy.
Valto?
fuckboys: 12:18pm On Mar 29
OgogoroFreak:
Valto?
ah abeg no put me for Wahala o. Not Valt.o.
Enyinne(f): 12:22pm On Mar 29
Cworth
OgogoroFreak:
Valto?
oaice: 12:30pm On Mar 29
I am your Plug for Original Felicity inverters and Must Inverters directly from the Factory/Source.
Selling genuine Felicity and Must Products directly from Company Warehouse at the best prices.
Beware of fake products and buy directly from the source with warranty.


Felicity Pure Sine Wave Inverters

FL-IVPS1512 Li 1.5KVA 12V - ₦260,000.00
FL-IVPS2512 Li 2.5KVA 12V - ₦418,000.00
FL-IVPS2524 Li 2.5KVA 24V - ₦418,000.00
FL-IVPS3524 Li 3.5KVA 24V - ₦518,000.00
FL-IVPS5024 Li 5KVA 24V - ₦733,000.00
FL-IVPS5048 Li 5KVA 48V - ₦733,000.00
FL-IVPS7548 Li 7.5KVA 48V - ₦840,000.00
FL-IVPS10048 Li 10KVA 48V - ₦1,230,000.00
FL-IVPM5048 Li 5KVA 48V with 120A MPPT - ₦999,000.00
FL-IVPM7548 Li 7.5KVA 48V with 120A MPPT - ₦1,097,000.00
FL-IVPM10048 Li 10KVA 48V with 120A MPPT - ₦1,454,000.00
FL-IVQM3524 Li 3.5KVA 24V hybrid inverter - ₦955,000.00
FL-IVGM5048 Li 5KVA 48V hybrid inverter - ₦1,356,000.00

Felicity High PV Voltage Inverters

FL-IVEM3024 3KVA 24V - ₦510,000.00
FL-IVEM5048 5KVA 48V - ₦600,000.00
FL-IVEM6048 6KVA 48V - ₦660,000.00
FL-IVEM8048 8KVA 48V - ₦1,045,000.00

Felicity MPPT Controllers

FL-SCCM3024 Li 30A
FL-SCCM4524 Li 45A
FL-SCCM4548 Li 45A
FL-SCCM6048 Li 60A
FL-SCCM8048 Li 80A
FL-SCCM10048 Li 100A
FL-SCCM12048 Li 120A


Felicity Lithium Batteries:
FL-LPBF24200 24V 5KWH
FL-LPBF48100 48V 5KWH
FL-LPBF48150 48V 7.2KWH is
FL-LPBF48200 48V/51.2V 10KWH
FL-LPBF48250 48V/51.2V 12.5KWH
FL-LPBF48300 48V/51.2V 15KWH IS
FL-LPBF48350 48V/51.2V 17.5KWH
FLA48300 51.2V 15KWH (7-year warranty)


MUST INVERTERS.
MUST LiFePO4 Battery.



Call or Dm on Whatsapp. 0913244twosixfive3