Juror: 8:59am On Feb 04
GloryJoyeux:


Sundry is the original OEM for Sms, welion etc inverters. The newer models with ‘actual’ dual mppt controllers work brilliantly and as you can see, I’ve established communication via solar assistant with it.

Cworth batteries have been incredible, they actually use brand new cells. I established communication using CAN via pylon protocol and so far so good. I have done up to 0.5c on them with no issues.

Cworth s surprised me, they have been keeping up with the Jinko s in of yield, sometimes even outperforming the jinkos. Believe me, if maybe I didn’t have the raw data, i wouldn’t have believed it’s possible.

Most importantly, #knocks on wood

Sundry or you meant Sunfield ?
Juror: 9:11am On Feb 04
Dam5reey1:
Na the same people will still come back to ask which brand is that? sad

You can't please people!

Which brand is the cell ? lol
BigDickProblems: 10:12am On Feb 04
Juror:


Did you set the battery voltage in the CC ?
Set it yourself, then also use a multimeter to check the battery voltage directly, don't trust the CC's display voltage, use the multimeter's reading to set your bulk and float on the CC, you can reduce the values by 0.2 too just to give some room.
Check if there's any changes.

Bro, I am using my Pwm Jejely. Besides, I just learnt some few things about the PWM CC.

Just yesterday, I was able to get the highest wattage ever (beating the MPPT) by adjusting some settings on it. I have different battery options ( 2)and customization options to get a good charging wattage from my s.

My Temporary Solution
So once my battery is full, I change the settings to a lower options on the WPM to keep the voltage at float even while it’s in use. Another option I try sometimes is when my battery is full via WPM, I rewire it back to my MPPT to keep the battery afloat. Here the MPPt is better because it usually keeps my battery between 13.6 and 14.0 while battery is being used. But the WPM, no matter the float voltage settings, will keep it between 13.3V and 13.4V while being used.


My conclusion, aided by research, is that the new brands of Felicity (without the button) has some factory issues. Just go to google and type “Felicity charge controller error 04”, and check comments under those Facebook and tiktok videos, then you’ll agree with me.
justcallmenuel(m): 12:33pm On Feb 04
16pcs of 430w Africell solar s, 8pcs of 220Ah Fenicity tubular batteries, 2pcs of 60A sms mppt charge controllers, and other accessories ready for delivery to Ado- ekiti.

We deliver to your location safely without any hassle!!

Call/whatsapp me on 08168986461 to place your orders…. Tested, Trusted and verified!!

#Manuelsolar

justcallmenuel(m): 12:38pm On Feb 04
HAVE YOU PATRONIZE ME BEFORE If not please patronize me, me, and refer my brand. We are RELIABLE!!! Thank you

justcallmenuel(m): 5:30pm On Feb 04
600 metres of 6mm DC solar cable dual core ready for delivery to magodo phase 1, Lagos state..

Call/whatsapp me 08168986461

Iinnov8: 5:59pm On Feb 04
Powmr 60A MPPT Solar Charge Controller
Price: 91,500

8-way breaker box. Can accomodate 4 units of 2P (double pole) breaker or SPD
Price: 5,000

Tomzn 2P 600V DC SPD
Price: 12,000

Tomzn 2P 275V AC SPD
Price: 10,000

Tomzn 2P 60A DC Breaker
Price: 8,500

Tomzn 2P 16A AC Breaker
Price: 5,500

Tomzn 2P 60A adjustable over/under voltage protective device
Price: 12,500

chris81964(m): 7:08pm On Feb 04
jonescosmos:
Nice work,
I don't mean to counter or criticize the work done. Just a pointer to the future problems that might arise.

1. THOSE CABLES THAT HAD TO RUN UNDER THE INTERLOCKED PAVES SHOULH HAVE BEEN MARINE GRADED PV CABLES. BEACSUE THE SHIELDS WILL BREAKDOWN DUE TO HUMIDITY AND MIGHT LEAD TO BRIDGING AND SPARKS ON THE LONG RUN.
2. THOSE DIN RAILS IN THE PLASTIC DISTRIBUTION BOXES OUTSIDE SHOULD HAVE BEEN REPLACED WITH OUTDOOR GRADED RAILS, BECAUSE THEY WILL CORODE WITH TIME DUE TO HUMIDITY.
3. THE SCREWS, BOLTS AND NUTS SHOULD BE COPPER OR BRASS COATED TO AVOID COROSION.


One again, Nice job. Kudos.

Thank you. I always welcome constructive criticism. It has been forwarded to the tech team.

5 Likes

chris81964(m): 7:09pm On Feb 04
mctfopt:


I wish people who build houses could give provision to having the house powered by renewable energy and thus make provision for some of these things like output DBs, input source and PV conduit point. Your people had to go through hell to provide this. Good job especially on the wall cracking which was just enough as was needed.
We don't normally do this. It was a massive learning experience for us.

3 Likes

GloryJoyeux: 7:26pm On Feb 04
.
GloryJoyeux: 7:32pm On Feb 04
.

1 Like 1 Share

GloryJoyeux: 7:40pm On Feb 04
.

2 Likes

zenith4biz(m): 9:47pm On Feb 04
GloryJoyeux:


Once in a while. It can go from 700w to 3000w. The higher the wattage the faster it’ll cook.

I usually set it to 2000w and it boils egg in 8mins.
Thanks
zenith4biz(m): 9:48pm On Feb 04
My Qasa 300w iron got delivered today, I was sceptical about the weight and efficiency but it turns out to be very effective.

If you are looking for energy efficient dry iron go for qasa.

3 Likes

Ferdiwar: 9:56pm On Feb 04
No sir.

Juror:

Those parameters are just for comms aren't they ?

1 Like

Ferdiwar: 10:07pm On Feb 04
Mine doesn't really stay on as it goes off and on making difficult use it for cooking and I don't seem to be in the mood to by the control 😓😞😔

GloryJoyeux:


Once in a while. It can go from 700w to 3000w. The higher the wattage the faster it’ll cook.

I usually set it to 2000w and it boils egg in 8mins.
Alienwarfare: 9:37am On Feb 05
How will you connect 30 s to 3 hybrid inverters? are 36v and 14a

jonescosmos(m): 12:20pm On Feb 05
5S2P (5 s in Series, Then Parallel 2 Strings of that 5 s to get 10 s) in Three places.

Finally, each 5S2P goes to each Inverter.

Alienwarfare:
How will you connect 30 s to 3 hybrid inverters? are 36v and 14a

1 Like

prince4pro2: 3:35pm On Feb 05
prince4pro2:
Pls guys i got 2 350w Canadian pannels connected via parrarell to 80a powmr pwm cc and 100ah gel battery. My cc receive highest 70w giving highest 5.5a. pls what could be the reason. I called my installer he said I should add more pannels,which I hv paid him to come install more 2 pannels of same 350 Canadian.

Pls guys what exactly can I do. Will Mppt cc solve this issues.? I wanted to get Mppt cc but my installer said the extra to pannels will help the situation. Pls guys I need una input.

Pls guys help a brother oooo

I hv added two more pannels. What I hv now is highest 8a and highest 90w according to the charge controller
Ifexabc: 4:46pm On Feb 05
Good Day....

Our product offerings include, but are not limited to, the following:

JA 580 Mono Solar s - Bifacial
5kWh/48V BYD/Leoch Lithium Batteries
11.7kWh/48V Leoch Lithium Batteries
5kWh High Voltage Deye Batteries
String Inverters-25KW/50KW/100KW/120 Goodwe brand
Hybrid Inverters 5KW - 48V - single phase - Voltronic
Hybrid Inverter 8 & 12kW - 48V - 3 phase - Deye
Hybrid Inverter 20 & 50kW - 160V-800V - 3 phase - high voltage - Deye

We believe that these high-quality products would be an excellent fit for your business. We would be thrilled to have you our list of esteemed dealers and work together to expand the reach of these products.
Please let us know if you are interested in exploring this partnership further. We also sell Perkins, and MWM Gas Generators ranging from 15kva-2500kva...

580w s = ₦150,000 EACH (10yrs Warranty and 25yrs Lifespan)

Dam5reey(m): 5:31pm On Feb 05
Sunlith Power Lithium battery capacity testing.



https://www.youtube.com/watch?v=4M39XFKPdCI
obitobe: 5:47pm On Feb 05
I doubt if those s are original Canadian s

what are the s specification, if possible send picture of the back where the spec is.

prince4pro2:


I hv added two more pannels. What I hv now is highest 8a and highest 90w according to the charge controller
Alienwarfare: 6:05pm On Feb 05
jonescosmos:
5S2P (5 s in Series, Then Parallel 2 Strings of that 5 s to get 10 s) in Three places.

Finally, each 5S2P goes to each Inverter.


My problem with that it is 36.25V x 5 = 181.25V which is very close to the 195V max PV voltage. Will it be ok?
Juror: 6:34pm On Feb 05
Ferdiwar:
No sir.

I think they're just for comms. They can't do anything when connected normally.
Juror: 6:37pm On Feb 05
Alienwarfare:


My problem with that it is 36.25V x 5 = 181.25V which is very close to the 195V max PV voltage. Will it be ok?
If 36.25V is actually the Voc and not Vmp then you should be fine.

1 Like

bleexInc(m): 8:42pm On Feb 05
Hello house,
Can anyone suggest a good low budget lithium battery with price?
HeavenlyBang(m): 9:59pm On Feb 05
bleexInc:
Hello house,
Can anyone suggest a good low budget lithium battery with price?

Cc: Valto

1 Like

jonescosmos(m): 7:34am On Feb 06
Oh yes, it is ok. In as much as you ain't crossing the 195V max line.

Alienwarfare:


My problem with that it is 36.25V x 5 = 181.25V which is very close to the 195V max PV voltage. Will it be ok?

1 Like

kristien4(m): 8:24am On Feb 06
Juror:


Do the battery have communication between them ?
Yes they do.

Reply)