NewStats: 3,261,711 , 8,174,883 topics. Date: Friday, 30 May 2025 at 09:16 AM 30y376z3e3g |
Solar Energy, A Complement To FTA (2757566 Views)
Juror: 5:45pm On May 02, 2023 |
tsiriman:What's your battery chemistry, specs and s capacity? |
Juror: 5:47pm On May 02, 2023 |
Hybrid600:Were they drained? |
Juror: 5:49pm On May 02, 2023 |
Peterlove11:What's your battery chemistry, specs and s capacity. |
earthrealm(m): 5:49pm On May 02, 2023 |
vta2008: They are playing safe, usually cos majority of owners arent so knowledgeable or the installer himself. The weakest link is usually the battery... A dry iron consumes btw 800watts to 1400w, whilea steam iron between 1600w and 2500watts. Now if you have 4 batteries, you may escape damage to the batteries if using dry iron. Of stated wattage range above., But steam iron will likely damage the battery. Always have the c/10 rule at the back of your mind when using leadacid batteries. Lithium batteries on the other hand has no issues with load and can do 1c, though 0.5C is the norm. C in this scenario is capacity of the battery in AH 3 Likes |
tsiriman(m): 6:00pm On May 02, 2023 |
Juror: 28kWh DIY lifepo4 batteries made up of 2units of 48V 280Ah lifepo4 banks. capacity is 6kW. 1 Like |
Iinnov8: 8:25pm On May 02, 2023 |
60A Powmr MPPT Solar Charge Controller. Price: 52,000 firm. ________________________________________ Original 1000V 63A double pole original Tomzn DC breaker Price: 6,000 firm ________________________________________ 3000W Changi Transformerless pure sinewave Inverter (no charging function) with battery voltmeter. Ideal for s on a budget and for keeps as rainy-day backup. Actual/Continuous power is 1500w. Peak power is 3000w. Very low idle watts consumption. Has protection against overload and surges from sparks Inverter capacity tested using the following household appliances: 1. 80w non-inverter Haier Thermocool 100L deep-freezer + >120w 5ca5" Hisense Smart TV + 400w Maxi 10kg washing machine + 70w slim Sony PS3 + 65w laptop power pack + 33w Qasa rechargeable + 400w Royal blender ā >1,000w rated appliances all loaded on inverter at once 2. Overload protection kicked in when i plugged in only a pressing iron rated 1,600w Videos of test available on request Price: 59,000 firm
|
Hybrid600: 8:28pm On May 02, 2023 |
Since he never called to complain after the installation about power going off, they weren't drained Juror: |
ojeysky(m): 9:59pm On May 02, 2023 |
tsiriman: Your battery spec makes the difference Bro.... @vta2008 should not try what you are doing frequently on his own set-up..... Battery type is very important in renewable energy. 3 Likes |
Peterlove11: 10:20pm On May 02, 2023 |
Juror: 4 x 12v 220ah tubular battery. 8Ć 270w with an additional 280w connected 3S3P |
temitimx19(m): 12:33am On May 03, 2023 |
Hello house, any solar expert in Kaduna here?
|
Loneley: 8:38am On May 03, 2023 |
Hi guys, just trying to get into solar. With a budget of 1 million or thereabouts, what sort of setup would I be able to put together?
|
zeestone99(m): 9:26am On May 03, 2023 |
Available now Solaria 390w solar all black Brand new Price - 95k
|
zeestone99(m): 11:06am On May 03, 2023 |
Sunmart vmii 5.5kw 48v 100a hybrid inverter 500vdc - 375k Sunmart Vmii 3.5kw 24v 100a hybrid inverter 500vdc - 320k Sunmart Vmiii plus 3.5kw 24v 100a hybrid inverter 500vdc - 340k Sunmart Vmiii plus 5.5kw 48v 100a hybrid inverter 500vdc - 395k Sorotec Revo Vmii 5.5kw 48v 100a hybrid inverter 500vdc - 420k Sorotec Revo Vmii 3.5kw 24v 100a hybrid inverter 500vdc - 340k Sorotec 5.5kw 48v 100a hybrid inverter 500vdc parallel version (includes parrallel kit) - 460k Sorotec 3.5kw 24v 100a hybrid inverter 500vdc parallel version (includes parrallel kit)- 380k Sorotec Revo vmiii 5.5kw 48v 100a hybrid inverter 500vdc - 440k Sorotec Revo vmiii 3.5kw 24v 100a hybrid inverter 500vdc - 360k Powmr 3.2kva 24v 80a 450vdc mppt hybrid inverter - 250k Powmr 3.5kva 24v 100a 500vdc mppt hybrid inverter - 340k Powmr 5.5kva 48v 100a mppt hybrid inverter - 385k Snadi 3.5kva 24v inverter wall mount (transformer) - 275k Snadi 5.5kva 24v inverter wall mount (transformer) - 350k Snadi 5.5kva 48v inverter wall mount (transformer) - 350k Epever tracer 60a mppt charge controller - 175k Epever tracer 100a mppt charge controller - 280k Must 100a mppt solar charge controller - (out of stock) Must 60a mppt solar charge controller - 130k Must 80a mppt solar charge controller - 140k Fangpusun flexmax 80a mppt charge controller - 270k Fangpusun flexmax 60a mppt charge controller - 200k Fangpusun 50a 12/24v - 90k 40amps mppt lumiax Bluetooth controller - 80k 60amps lumiax Bluetooth mppt controller - 145k 60amps 12/24/36/48v powmr mppt - 70k Greenpole 48v 100ah lithium battery - 950k Avr/current limiter 60a (Tomzn) - 9k Avr/current limiter 63a 4pole (tomzn) - 23k Change over breaker/MTS - 5k Change over breaker/MTS 4pole - 15k DC SPD 500v - 8k DC spd 1000v (tomzn)- 9k Ac spd 385v - 8k Ac spd 275v (tomzn) - 9k Ac spd 4 pole - 15k DC Voltmeter (5v- 120v ) - 2k DC Voltmeter (8v- 100v / with battery indicator and %) - 4k Watt meter - 15k Mc4 connectors - 550 Mc4 y connector 2 in 1 - 2.8k Mc4 y connector 3 in 1- 4k Mc4 y connector 4 in 1 - 8k Programmable timer 15a UK pkug - 9k Programmable timer 25a - 9k solar DC fuse holder 1 pole (tomzn) - 3k Solar DC fuse holder 2 pole (tomzn)- 5.5k Solar DC fuse (10a/16a/20a/25a/30a) - 1.5k DC breaker 10a 600v double pole (tomzn)- 6k DC breaker 16a 600v double pole (tomzn) - 6k DC breaker 20a 600v double pole (tomzn) - 6k DC breaker single pole (32-63a) - 3k DC breakers double pole 63a - 5k DC breaker double pole 100a - 9k Dc breaker double pole 125a - 10k DC breaker double pole 100a (tomzn)- 9k Dc breaker double pole 125a (tomzn)- 11k Dc breaker mccb 250a double pole - 25k Ac breaker double pole 10a (Tomzn)- 4k Ac breaker double pole 16a (Tomzn)- 4k Ac breaker double pole 32a (Tomzn)- 4k Ac breaker double pole 63a (Tomzn)- 4k Ac breaker double pole 10a (Chint)- 4k Ac breaker double pole 16a (Chint)- 4k Ac breaker double pole 32a (Chint)- 4k Ha02 battery balancer - 35k Busbar (Red and Black) - 20k Automatic transfer switch (ATS) 63a (wall mount) - 24k Automatic transfer switch (ATS) 63a (tomzn) - 21k (out of stock) Automatic transfer switch (ATS) 100a (tomzn) - 22k Automatic transfer switch (ATS) 125a (tomzn) - 24k 6 in 1 Ac display meter ( watts, voltage,kWh,amps, freq, power factor) - 15k 6way breaker enclosure - 3.5k 9 way breaker enclosure - 4.5k 12way breaker enclosure - 5k DM for other items. Call/chat - 08117398294 1 Like |
vta2008: 1:04pm On May 03, 2023 |
tsiriman: Thank you š |
vta2008: 1:05pm On May 03, 2023 |
Peterlove11: Thanks a lot. I'm always carefully not to have plenty heavy loads on at the same time. š |
Feranmhine: 1:06pm On May 03, 2023 |
Please, How many hours would an inverter of 500watts of load use from a 12V/200Ah battery? |
Feranmhine: 1:21pm On May 03, 2023 |
Also, do we use a power factor of 0.7 for calculation in the battery
|
vta2008: 1:39pm On May 03, 2023 |
earthrealm: The pressing iron uses around 850W max according to my wattmeter. The 4 pieces of tubular battery are setup to make a total of 24V 440AH. Do I apply the C/10 rule per battery or the entire setup? Thanks NOTE: I mainly use the dry pressing iron and oven when the solar s are at their maximum output of about 800W |
vta2008: 1:41pm On May 03, 2023 |
Juror: The pressing iron uses around 850W max according to my wattmeter. The 4 pieces of tubular battery are setup to make a total of 24V 440AH. How do I avoid damaging the batteries? Thanks NOTE: I mainly use the dry pressing iron and oven when the solar s are at their maximum output of about 800W |
earthrealm(m): 4:02pm On May 03, 2023 |
vta2008: the c/10 is same where you apply it singly or cumulatively. c/10 of 440ah is 44amps, so you shud try to keep ur total running load below this at sundown/no sun periods...multiply this by the system voltage to get about 960watts. ie 24v x 44ah. the iron of 850watts wudnt damage your battery.....i even use a steam iron of 1200w on my 4 flooded batteries...no issues. this is because the thermostat of the iron regulates the load..heats for 60secs or so and turns off..n cycles again. am sure the battery might hv gotten damaged, if it was a constant 1200 watts draw..like sumo/ac etc. pls the quality of battery plays a big role as thicker plated batteries are more durable. 2ndly flooded batteries are tougher n recover from abuse better than the normal dry cells. find below my ranking of batteries lifepo4 >>> 2v 600ah and above cells >>>>>> flooded battery/AGM >>>>>>>>>Other sealed battery types 1 Like |
kiekie1(m): 9:52am On May 04, 2023 |
zeestone99: THe poster feels the quote was OUTRAGEOUS ![]() 1 Like |
kiekie1(m): 9:54am On May 04, 2023 |
Functionalsol: Sold n installed several without issue. us for discounted price. Afripower Authorized dealer Smartcell global services CALL:: 081-350-31951 WHATSAPP::: http://.us/w/?c=a46ea5 |
samir101ng(m): 12:38pm On May 04, 2023 |
Juror: This last part is the reason why i have never bothered to patronize our local sellers here flooding the forum daily with their adverts without any meaningful contribution to this body of knowledge. They promise and sweet talk but once money has changed hands it turns into a different ball game entirely. For those of us up country, who do you turn to for help ? Yes, i can listen to "some" recommendations from reputable s with long term history and reputations to protect but last last the risk always lies on your head. The fact that a seller needs to always go and get stuff from other sellers and doesn't have a shop with stock is a red flag for me. Trust is rare these days especially for us in Nigeria which is why your better off sometimes buying directly from the retailers/dealers rather than middle men adding up costs to make a buck. 9 Likes |
Pojomojo: 3:12pm On May 04, 2023 |
Juror:What's this? |
Pojomojo: 3:13pm On May 04, 2023 |
zeestone99:Thank you. I will call |
Pojomojo: 3:14pm On May 04, 2023 |
Peterlove11:Thank you. |
herrlekan(m): 3:16pm On May 04, 2023 |
Pojomojo: what you see is what you get. IYDGIFAI 1 Like |
Pojomojo: 3:16pm On May 04, 2023 |
![]() herrlekan: |
vta2008: 3:43pm On May 04, 2023 |
earthrealm: Thank you so much. My mind is at rest now š. My pressing iron and air fryer do the same power on and off cycle thing so I'm good. Will continue operating them at maximum sun availability only. The batteries are Haustrom brand bought from an authorized dealer so hopefully the quality is okay šš |
temitimx19(m): 5:21pm On May 04, 2023 |
Hello house which of these solar charge batteries during rainfall, Monocrystalline or polycrystalline. Thanks
1 Like |
contease(m): 6:12pm On May 04, 2023 |
temitimx19: "Open sidebar Solar s and batteries. which of these solar charge batteries during rainfall, Monocrystalline or polycrystalline. Thanks ChatGPT Solar s, whether monocrystalline or polycrystalline, generate electricity by converting sunlight into electrical energy. However, during rainfall, the amount of sunlight reaching the solar is reduced, which can affect the charging of batteries. Therefore, neither monocrystalline nor polycrystalline solar s can directly charge batteries during rainfall. However, if the solar is connected to a battery storage system, the battery can be charged during periods of sunlight, and the stored energy can be used during periods of reduced sunlight or rainfall. It's worth noting that polycrystalline solar s are generally less efficient than monocrystalline s, meaning they produce less electricity per unit area of solar . However, the difference in efficiency is typically small and may not significantly affect the ability of a solar to charge a battery in varying weather conditions. Free Research Preview from ChatGPT 4 Likes |
contease(m): 10:25am On May 05, 2023 |
In trying to understand what 50% DoD for a 24v norminal system in Volts... Eg, from 29v to 20v, 21v,22v,23v or 24v use? considering that at rest, a Lead Acid battery would always drop to 26.xV without trickle charge (Float), I got this unsatisfactory info: "Open sidebar 24V Battery Depth Discharge. what is 50% DoD for a 24v norminal system in Volts... Eg, from 29v to 20v, 21v, 22v, 23v or 24v use? considering that an rest, a Lead Acid battery would always drop to 26.xV without trickle charge (Float) ChatGPT If the nominal voltage of a 24V system is assumed to be 24V, then a 50% depth of discharge (DoD) would mean that the battery has discharged half of its capacity, which would equate to approximately 12V. However, it's important to note that the voltage range you provided (from 29V to 20V) is a bit wider than what would typically be expected for a 24V battery system. Additionally, the resting voltage you mentioned (26.xV) would likely only be applicable after the battery has been fully charged and then allowed to rest for some time without any load or charging. In general, the voltage of a lead-acid battery will vary depending on a variety of factors such as temperature, charge level, and load, so it's difficult to give a specific voltage range for a 50% DoD without additional information about the specific battery being used and the conditions under which it is being operated. Send a message. Free Research Preview. ChatGPT may produce inaccurate information about people, places, or facts. ChatGPT May 3 Version" Can we have more indept info better than the above please from any member in the house... The scenerio above is considering an off grid instance where at 5pm, the sun is completely out and loads depend on the backup till next morning |
Free To Air Satellite Tv General Thread
Viewing this topic: Darey00(m), samsard(m), Haykay2001, bkuranga(m) and 2 guest(s)
(Go Up)
Sections: How To . 66 Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or s on Nairaland. |