pranil(m): 3:46pm On Jun 11, 2018 |
NiyiOmoIyunade: If you have 2P DC breaker why not disconnect both + ve and -Ve- The way I normally do it is to use DC breaker immediately after the battery so it can safely switch off all inverter, charge controller and the shunt |
ebocoms: 3:52pm On Jun 11, 2018 |
Thanks @NiyiOmoIyunade for the great help. I used Microsoft Visio 2010 for the design. The meter came with attached cable in the picture below. Guess is the one you are talking about. [img][/img] NiyiOmoIyunade:
|
ebocoms: 4:02pm On Jun 11, 2018 |
Ok thanks @pranil. Is it the -Ve from the inverter that would through the breaker or the the -Ve (jumper cable) that would through the breaker B? pranil: |
Saipro(m): 5:55pm On Jun 11, 2018 |
bigrovar: My research leads me to believe you're on to something |
Saipro(m): 6:29pm On Jun 11, 2018 |
sinistrian:The Fangpusun are clones of the Victron in this regard. However, after the initial minutes of hunting the grid, it seems to constantly do sweeps. Data extrapolated from my 5-day old Victron BlueSolar MPPT 150/70 (VE.CAN model) |
Janyves(m): 7:55pm On Jun 11, 2018 |
MAboyarin: That function is best left on the "default" mode(13.7v/27.4v).....its got to do with charge voltage, the customized mode involves some pcb component tweaking which alters it to some voltage values depending on the level of tweaking. |
BLS1: 9:09pm On Jun 11, 2018 |
NiyiOmoIyunade: Thanks so much for the response. Truly the insights and the advice you all give is truly priceless. Will probably continue alternating batteries for another week or two before I "parallel" them together and will you soon on the desulphators. Thanks again. |
Reprobate: 7:51am On Jun 12, 2018 |
can someone educate me on the max instantenous current draw from a batt bank, without damaging the batt. eg my 48v 200ah bank, going by 10hr discharge rate, can I assume 20amps is the max draw, thus max allowable instantenous load is 20a x 48v = 1kw load? |
BRIGHTSOLAR(m): 7:53am On Jun 12, 2018 |
DROPSHIPPING AND ONLINE DELIVERY OF RENEWABLE ENERGY MATERIALS INVERTER MICROTECH INVERTER 900VA,12V N46,000 1.1KVA,12V N53,000 1.6KVA/24V N72,000 2KVA/24V N80,000 2.6KVA/36V N105,000 3.6KVA/48V N170,000 5.2KVA/48V N340,000. 5.5KVA/96V N340,000 10KVA/180V N790,000 PRAG INVERTER 1.1KVA,12V N70,000 1.2KVA,12V N90,000 1.5KVA/24V N110,000 2.5KVA/24V N125,000 3KVA/24V N170,000 4KVA/48V N320,000. 5KVA/96V N300,000 7.5KVA/120V N500,000 710KVA/180V N600,000 KELVIN INVERTER 2.5KVA/36V N125,000 2.5KVA/48V N125,000 3 KVA/48V N170,000 5KVA/48V N340,000. 5KVA/96V N290,000 7.5KVA/120V N550,000 10KVA/180V N750,000 MUST POWER STAR INVERTER 4kva 3000W 24V N 220,000 4kva 3000W 48V N 260,000 5kva 4000W 48V N 350,000 6kva 5000W 48V N 400,000 7.5kva 6000W 48V N 450,000 HYBRID INVERTER VOLTRON SERIES 1.4KVA/12(30A N65,000 2.4KVA/24V50A N97,000 3KVA /48V 60A MPPT N220,000 5KVA /48V 60A MPPT N310,000 7.5KVA /48V 60A MPPT N430,000 10KVA /48V 100A MPPT N750,000 15KVA /48V 60A MPPT N850,000 15KVA /48V 120A MPPT N890,000 BATTERY LONG BATTERY LONG BATTERY 12V/100AH N 67,000 LONG BATTERY 12V/150AH N 100,000 LONG BATTERY 12V/200AH N 120,000 MONBAT SLIM BATTERY MONBAT BATTERY 12V/100AH N 75,000 MONBAT BATTERY 12V/200AH N 125,000 MONBAT BATTERY 12V/210AH N 120,000 ELSON BATTERY ELSON BATTERY 12V/200AH N 115,000 MICROTEC BATTERY MICROTEC BATTERY 12V/200AH N 105,000 EASTMAN BATTERY EASTMAN 12V/200AH TALL TUBULAR BATTERY N110,000 EASTMAN 12V/200AH TALL TUBULAR GEL BATTERY N115,000 GLT BATTERY GLT BATTERY 12V/100AH N 45,000 GLT BATTERY 12V/150AH N 65,000 GLT BATTERY 12V/200AH N 90,000 ZEEDIX BATTERY ZEEDIX BATTERY 12V/100AH N 45,000 ZEEDIX BATTERY 12V/150AH N 70,000 ZEEDIX BATTERY 12V/200AH N 90,000 RITAR/COWIN BATTERY RITAR BATTERY 12V/100AH N 62,000 RITAR BATTERY 12V/150AH N 90,000 RITAR BATTERY 12V/200AH N 125,000 PRAG BATTERY PRAG BATTERY 12V/200AH N 140,000 PATTERN BATTERY PATTERN BATTERY 12V/200AH N105,000 QUANTA BATTERY QUANTA BATTERY 12V/100AH N 70,000 QUANTA BATTERY 12V/150AH N 98,000 QUANTA BATTERY 12V/200AH N 125,000 BATTERY RACK BATTERY RACK 2 BATTERY N 15,000 BATTERY RACK 4 BATTERIES N 30,000 BATTERY RACK 8 BATTERIES N 50,000 CHARGE CONTROLLER ROY SOLAR SERIES 20A 12/24V PWM CONTROLLER N 20,000 30A 12/24V PWM CONTROLLER N 25,000 40A 48v PWM controller (LED) N 50,000 30A 96v PWM controller (LCD) N 120,000 60A 48v PWM controller (LCD) N 95,000 COWIN SERIES 20A 12/24V PWM CONTROLLER N 15,000 30A 12/24V PWM CONTROLLER N 20,000 40A 12/24V PWM CONTROLLER N 25,000 50A 12/24V PWM CONTROLLER N 32,000 60A 12/24V PWM CONTROLLER N 41,000 40A 48v PWM controller (LED) N 25,000 50A 48v PWM controller (LED) N 32,000 60A 48v PWM controller (LED) N 50,000 COWIN MPPT SERIES 40A 12/24/48v MPPT controller (LCD) N 80,000 60A 12/24/48V MPPT controller (LCD) N 130,000 EPEVER MPPT SERIES 12/24/48 /45A N 145,000 12/24/48 /60A N165,000 FANGUNPSUN MPPT SERIES 30A 24V N40,000 60A 48v N150,000 70A 48v N170,000 80A 48v N180,000 SOLAR S JOY SOLAR 150w MONO -N32,000 200w MONO -N33,000 260w MONO -N54,000 320w MONO -N73,000 TRINA SOLAR 300w MONO -N85,000 320w MONO -N110,000 YINGLIN SOLAR 100w POLY -N22,000 150w POLY -N33,000 200w POLY -N39,000 260w POLY -N51,000 310w POLY -N62,000 100w MONO-N25,000 150w MONO -N33,000 200w MONO -N39,000 260w MONO -N59,000 320w MONO -N74,000 CANADIAN SOLAR MONO- 290w. N60,000 330w. N66,000 POLY 270w. N45,000 275w. N59,000 ACCESSORIES PROGRAMMABLE Digital timer 15A N7,000 PROGRAMMABLE Digital timer 25A N9,000 BATTERY BALANCER HA02 48V 35K DC CIRCUIT BREAKER 63A/120V---500V 2 POLE N 8,000 DC CIRCUIT BREAKER 125A/500V 2 POLE N 14,000 COMPLETE SOLAR SOLUTION Call-07058562938 Bright Solar Power WHATSSAP 08187995847 FOR PURCHASE/ DELIVERY INSTALLATION NATIONWIDE |
Barezzi(m): 9:39am On Jun 12, 2018 |
Yes. The batteries wont be damaged if the rate of discharge is exceeded, only its effective capacity will be reduced (Peukert's law) Reprobate: |
Chuckdee(m): 9:56am On Jun 12, 2018 |
Barezzi: Hi Barezzi, Please how did you achieve using the grid to power your AC load w/out the inverter charging the batteries at the same time? I use a Magnum Inverter and haven't been able to see a setting that will allow me to turn off the charger completely (can only regulate the charging rate) I would ideally want an automated arrangement that would allow grid power to thru the inverter when available from 6pm to midnight w/out the inverter charging my batteries with that grid power |
Barezzi(m): 10:05am On Jun 12, 2018 |
I sold my Magnum inverter and bought a Gennex hybrid. ![]() It has settings that allow intentional islanding and grid thru with the charger off. I have forgotten, but i think the magnum allows you to set the charge current to zero. Chuckdee: |
GeorgeD1(m): 10:43am On Jun 12, 2018 |
chuckdee, if you're using the magnum ms4348pe with the advanced remote me-arc50, there is a button for turning off the charger completely. Also, you can program the charger to cut-off and cut-in at certain times of the day, say from 6am to 6pm. This among many options make the magnum a very robust beast of an inverter.
|
kiekie1(m): 10:47am On Jun 12, 2018 |
makavele: Good to meet with you ![]() 1 Like |
kiekie1(m): 10:49am On Jun 12, 2018 |
GeorgeD1: Good point ![]() |
kiekie1(m): 10:58am On Jun 12, 2018 |
Ritar 12v 105a mtn used front access telecom batteries very limited stock Procured: 65 units In stock: 10 units Condition: Very Good ![]() Location: Lagos state"we waybill to various states"t&c applies " Price : N27,000 ; Smartcell global services 081-350-31951 1 Like |
makavele: 10:58am On Jun 12, 2018 |
kiekie1: Anytime! anyday! 2 Likes |
totalgreen01: 11:07am On Jun 12, 2018 |
Trojan L16P 6 Volt, 420 AH looking for Trojan L16P 6 Volt, 420 AH, any one has ? |
godspeed: 1:06pm On Jun 12, 2018 |
godspeed: Hello house So much confusion everywhere ooo! So I got a professional installer to take a look at my set up and confirm why the battery is not charging. First thing he said is that instead of using 2 250watts s, I should have gone for 4 150 watts s, because this according to him, gives me more amperage - 8 amps each translating to 32 amps. He said the battery (220 ah) requires 22 amps to charge while I can use the excess amps to power my appliances. He claims the 2 s I have presently generates max of 12 amps which he claims can never charge the battery full. He also tested the voltage coming thru the CC and got ~36 volts, this he said is too much for the CC as it's designed for 12-24 volts and claims the excess volts is not healthy for the CC and it's preventing it from working optimally. I had him speak with my installer and he said why he used 250 watts is to get 24 volts which can be converted to more current to charge the battery. Both of them just left me confused with their technical jargons but both agree I need to change theCC to MPPT. When the professional guy says I need to add one more 250 watts to be able to get a full charge on the battery daily, my installer claims changing the CC to MPPT will fix the problem as it will convert excess volts to current which is sufficient to charge the battery full. So house, I'm really so confused |
Dam5reey(m): 1:15pm On Jun 12, 2018 |
I'm getting close to 15V from my Luminous inbuilt controller.. Hope I'm safe
|
godspeed: 1:52pm On Jun 12, 2018 |
Dam5reey: Pls can I see a pic of this inverter |
JUO(m): 2:48pm On Jun 12, 2018 |
[quote author=JUO post Flex max 80a fangpusun 156k Flex max 60a fangpusun 135k 50a-12/24v 45k. 46k 50aD-12/24v 60k 60a-12/24v/36v/48v 110k. 60aD-12/24v/36v/48v 125k 70a-12/24v/36v/48v 135k with display 45a-12/24v/36v/48v 75k 30a-12/24v 35k Battery balancer HA02 48v 35k Battery balancer Fangpusun 24v-25k MPPT- CONTROL 16K epever 30a+MT50 12/24v (CN) 50k epever 30a 12/24v 50k epever 40a 12/24v 56k epever 40AN 12/24v 60k BMV 702 FANGPUSUN 42K BMV 700 FANGPUSUN 38K ATS-220V/63A-16K Watts meter with clock and 50Hz/60Hz Monitor Analyser 7k PROGRAMMABLE Digital timer 15/16a 5k din rail PROGRAMMABLE Digital timer 25a 7k din rail/wall mount Energy efficient ceiling fan AC/DC '56' 6-36w 25k 080-987-337-09. 68353800][/quote] 96V to 384v mppt available. Maximum PV input 850v |
Dam5reey(m): 3:40pm On Jun 12, 2018 |
godspeed: 500VA version
|
pranil(m): 3:56pm On Jun 12, 2018 |
ebocoms: If you send the visio native file to me I can redraw but basically - battery -ve from the battery to DC breaker and then toshunt battery side same with +VE - from Battery +ve to breaker first and then to inverters, CC + VE ETC Also note DC breakers can have polarity and the side marked with +Ve symbol should be on the battery side ( side with the highest voltage of power flow possible) |
pranil(m): 4:20pm On Jun 12, 2018 |
godspeed: ![]() Stop thinking of Wattage, voltages etc, PV s are not generators. They are you diesel tanks Inverter is Generator while PV + Battery provides the energy to run the inverter ( Generator). A good installer then should match the correct voltages, currents etc based on the products used. Most important to think is Total energy required in the day The minimum you should target is in KWH is atleast 50 % of Battery capacity ( 2.4 Kwh for you I guess ) + amount of energy used during the sunny period in the day What you need a Quality MPPT CC preferably which can handle 100 V or Above input ( Voc) then you can connect s in series That way you reduce the cabling loss and the CC will wake up earlier in the morning and go to sleep late maximizing the usage of the 500 watt you should get typically 1.5 2 KWH on Average yield from 500 Watt s with correct Cc and installation - The Yield ( energy is important ) not the wattages, If you are using inverter/battery in afternoon you will have to calculate how many units you typically use in afternoon and increase the size to address that. in your case you have the possibility of to 250 x 2 ( 2 in series) or 250 x 4( 2 series, 2 strings parallel) or 250 x 3 ( 3 in parallel or series depending on CC) |
DMerciful(m): 4:22pm On Jun 12, 2018 |
He is not a professional installer! get an mppt cc and connect those two s in series and you are good. better still patronise installer from this forum and have rest of mind.
godspeed: 3 Likes |
godspeed: 5:29pm On Jun 12, 2018 |
DMerciful: Thanks What's the implications of connecting in series? Pls bear in mind that my Inverter is just 12 v and the maximum load by my calculations is 150 watts |
EnigmaticEnigma(m): 5:31pm On Jun 12, 2018 |
Does anyone have any experience buying batteries from Alaba??
|
Saipro(m): 5:53pm On Jun 12, 2018 |
Reprobate: Pretty risky assumption and could lead to early battery failure. Inverter and cabling inefficiencies usually total a minimum of 15% of the power (translated as 85% efficiency). Your 20A pragmatically becomes 17A (assuming C/10 discharge). Most FLA batteries won't safely take beyond C/8 as discharge (AGM often can tolerate higher). Assuming the stress limit of C/8, that's 21A (though I see no point in pushing batteries to their limits unless absolutely necessary). Then there's the issue of variable inverter self-consumption ... |
DMerciful(m): 6:01pm On Jun 12, 2018 |
Connecting in series will ensure ur system wakes up on time and sleeps late wrt sun rise and sunset however since your system is 12v and most 250w s are 35V Voc it means that connecting in parallel is fine but you need to get an mppt controller. This has the ability to convert excess voltage to current just to put it simply. me for this controller... See my signature
godspeed: |
ebocoms: 6:05pm On Jun 12, 2018 |
Kindly let me have the email to send the raw visio file to. It can also be ed from the dropbox link below https://www.dropbox.com/s/scchgdg4jjg0msq/SolarConnection-edited.vsd?dl=0 My email is ebocoms (at) yahoo (dot) com. Thank you. pranil: |
godspeed: 6:13pm On Jun 12, 2018 |
DMerciful: Lemme see a pic of the controller NB each of my is 24v |