Solar Energy, A Complement To FTA (2762927 Views)
Dam5reey1(m): 7:25pm On May 23 |
fuckboys: Did you buy bread or Haisic? Also the Fans on Haisic hardly kick in when loaded under 300w. Unlike some 2kva 12V inverters... The single Cooling is enough Haisic used a lighter casing. 3 Likes |
skywalker95(m): 7:26pm On May 23 |
I need assistance with my tubular battery. I just topped up with distilled water for the first time and I notice the battery is now dying faster than usual. I ensured the battery was fully charged before topping the water to prevent overfilling it and I have noticed no spilling since I filled it. For the past three days, the voltage drops to 24.5 once the sun goes down and it was not like this before.
|
dollarnaira: 7:34pm On May 23 |
skywalker95: Exactly when they are about to die. How old first? 1 Like |
adrusa: 7:35pm On May 23 |
skywalker95: You need to equalize the batteries. 1 Like |
skywalker95(m): 7:36pm On May 23 |
dollarnaira: Seven months. |
skywalker95(m): 7:37pm On May 23 |
adrusa: How do I equalize the battery? |
Ferdiwar: 7:39pm On May 23 |
When last did you equalize the batteries? skywalker95: |
Ferdiwar: 7:48pm On May 23 |
I don't know the details of your setup but this will give you an insight of how to go about it. https://www.tiktok.com/@spandertechnologies/video/7475013613036637446 skywalker95: 1 Like |
skywalker95(m): 7:49pm On May 23 |
Ferdiwar: I honestly don't know how to equalize the batteries. I only know the installer set the float to 27.8, absorption to 28.4 and equalization to 29.2. I thought the charge controller will equalize it at intervals using this settings but it did not occur to me that I've never seen it at 29.2. |
fuckboys: 8:02pm On May 23 |
Dam5reey1:i went for bread, but as per the fans, the bread inverter fans are always running round the clock even with little or no loads on the inverter. Don't know if it was designed that way. |
skywalker95(m): 8:10pm On May 23 |
Please, can someone using SMS charge controller teach me how to equalize my batteries using the CC or is there a way to use an external device to equalize the batteries?
|
mctfopt: 8:28pm On May 23 |
fuckboys: Oh, just that I never saw the load handling capacity of Bread. Would love 's review on that. What's Bread's PV voltage range? |
fuckboys: 8:38pm On May 23 |
mctfopt:mad Haisic below, compare them yourself 2 Likes |
Dam5reey1(m): 8:59pm On May 23 |
fuckboys: Thats one thing i like about the Haisic, the Fan is one Bigger and more Quiet.. without much load its silent 1 Like |
Dam5reey1(m): 9:01pm On May 23 |
mctfopt: Hopefully i may get one for test. 2 Likes |
omotoda(m): 9:18pm On May 23 |
fuckboys: Haha! Now you are talking.That itself is a disadvantage Reminds me of the days of that mercury 2.4kvs modified since wave inverter that the fan is always on. |
fuckboys: 9:43pm On May 23 |
[g
|
Dam5reey1(m): 10:30pm On May 23 |
fuckboys: These SMS ehn, their power no really reach 1.6kw before it starts beeping overload 1 Like |
Guyincna(m): 10:36pm On May 23 |
skywalker95:how long did you use this battery before topping it with distill water |
bbally: 11:15pm On May 23 |
Dam5reey1: The highest have done on the 1.6kw is 1.2kw 1 Like |
oloet: 11:55pm On May 23 |
Machiny:As the last born I recommend Firman as the interface looks very much like deye 1 Like |
iraybuju: 1:11am On May 24 |
fuckboys: What problem do people have with a running fan in inverter ? Is the inverter installed in your sitting room of bedroom. Abeg make una leave Watin them write for body of Moto, enter moto |
favouredbymercy: 1:44am On May 24 |
maklelemakukula: Good day Bro, did you still go ahead to use the 4 batteries temporarily? Please I need your review on this. I am thinking of doing something similar for a 24v setup. Please how far? |
mctfopt: 3:21am On May 24 |
Dam5reey1: That'll be awesome 1 Like |
mctfopt: 3:27am On May 24 |
samnaija: 4:13am On May 24 |
skywalker95: Equalization is an overcharge of the battery bank which is necessary in your case because you topped it . If you have the manual of your battery, check for the best equalization voltage for your batteries. What is the brand of your charge controller and batteries?. You have to take time to understand the charge controller settings dont rely on what your installer has done. Find out if your charge controller has a equalization settings you can activate immediately you want to equalize. Make sure the equalization last a minimum of 1 hr. You can repeat again to get the desired result. Here is a link to guide, not compulsory to use the exact voltages. https://northeastbattery.com/equalizing-charges/#:~:text=For%20a%2012%20volt%20battery,for%20at%20least%20one%20hour. |
maklelemakukula(m): 9:01am On May 24 |
favouredbymercy:No I did not. I just decided to wait for my battery to arrive(arrives in june). I dont want to hear stories that touch |
emekam12(m): 9:37am On May 24 |
I need one. How do I you? Iinnov8: |
Ealiserwest(m): 10:49am On May 24 |
Good morning. Please where can i get wifi dongle connection for SMS 4.2 kVA hybrid inverter
|
Dam5reey1(m): 11:39am On May 24 |
Androblaze, Boss, I need your , or you text me +23481323-94478
|
FLXX: 12:22pm On May 24 |
Which is a better option? 650W Jinko Solar Or 650W Bifacial Solar (Used don't the brand) I was told Bifacial s tend to capture more power. Not sure if Jinko Has Bifacial s I am a Novice |