Solar Energy, A Complement To FTA (2773759 Views)
Juror: 6:41am On Apr 24, 2024 |
chris81964:Ok.. these would fit in comfortably then. |
Juror: 6:46am On Apr 24, 2024 |
jonescosmos: This grounding matter keeps coming up, to-merge or not-to-merge, but most times it isn't easy to effect a second ground especially in rented apartments, so what to do? . The use of ATS could simply be due to periods of shutdown of the inverter due to low battery levels and not necessarily for malfunction even though I agree that a malfunction requires direct attention. The inverter installation would already have it's own overcurrent protection on it's output either by breakers or current limiters or the inverter itself as you have mentioned, so whatever fault occurring outside of that may not be the responsibility of the inverter and it's handlers except it gets a hit through the input section if left unprotected. |
Juror: 6:53am On Apr 24, 2024 |
adrusa: Unfortunately I have been searching if there are ready made retrofits that could serve that purpose. It would help a lot if load can be controlled based on battery's state of charge. |
ValtechEnergy(m): 7:27am On Apr 24, 2024 |
Valto: 1 Like |
bbally: 7:31am On Apr 24, 2024 |
QuoteJust1nce:Hello bro, am in Lagos and I will not mind to have the gadget My digit o7o3234nine394 |
jonescosmos(m): 10:02am On Apr 24, 2024 |
Juror: Dry s only activates at critical battery low alarm and deactivates at battery floating stage and will not even activate even if grid comes on but until the battery floats. Deye Smartload gives you the ability to activate this port when grid comes on, when SOC is at your choice level, when PV wattage reaches a certain level. The newest firmware update even makes it possible for the smartload to shut off if grid goes off and battery has not reached your desired smartload ON SOC. We are currently upvoting a TIME OF USE Option for the SMARTLOAD PORT. "If e no be panadol, e no fit be like panadol" 1 Like |
sharks776(m): 10:10am On Apr 24, 2024 |
jonescosmos: Am impressed 💯 But na for who get big pocket sha |
Hybrid600: 12:05pm On Apr 24, 2024 |
Omo this Deye eh.
1 Like |
EduTechTainMent: 12:58pm On Apr 24, 2024 |
QuoteJust1nce: Ain't you looking to sell the ODU as well? |
EduTechTainMent: 1:01pm On Apr 24, 2024 |
QuoteJust1nce: You now agree it's unlimited abi your initial reservation was just about the speed cap? |
EduTechTainMent: 1:07pm On Apr 24, 2024 |
Nexuspulse: This is one of the best alternative energy companies I know. Kept wondering why their products isn't in the 9ja market that much. Nice one 2 Likes |
QuoteJust1nce: 2:18pm On Apr 24, 2024 |
EduTechTainMent: For your own good, kindly Reduce your garri intake! 1 Like |
QuoteJust1nce: 2:20pm On Apr 24, 2024 |
EduTechTainMent: Nah |
kristien4(m): 2:39pm On Apr 24, 2024 |
Is it important to put breakers between battery and inverter? And can normal DC double pole breakers be used?
|
Danibestguy: 3:08pm On Apr 24, 2024 |
EduTechTainMent: Have you used their inverters before? |
EduTechTainMent: 3:31pm On Apr 24, 2024 |
Danibestguy: Nah. Just their LiFePO4 batteries. |
bassdow: 3:46pm On Apr 24, 2024 |
EduTechTainMent: nothing TRUEly is unLIMITed. There's always limit(s) one way or the other. |
bassdow: 3:59pm On Apr 24, 2024 |
Parser:you know there are people who don't know that something as little as 1-amps from a 200Volts source, is much deadlier than 12-amps from a 5Volts source. 2 Likes |
zeestone99(m): 4:11pm On Apr 24, 2024 |
Hello House The following are available now. INVERTER Sukam falcon 1kva/12v pure sine wave inverter - 140k Mpower 1.1kva/12v pure sine wave inverter - out of stock Afripower 1.7kva/24v pure sine wave inverter - 220k Afripower 2.5kva/24v pure sine wave inverter - 280k Cloud 1kva 50a pwm solar hybrid inverter - 175k 2kva 12v sunfield 80a mppt hybrid inverter - 300k Welion 4.2kva 24v 120a mppt solar hybrid inverter - 420k 6.2kva E-way 120a mppt hybrid inverter - 500k 8.2kva E-way 160a mppt inverter (2 trackers ) - 750k Sunmart vmii 5.5kw 48v 100a hybrid inverter 500vdc - out of stock Sunmart Vmii 3.5kw 24v 100a hybrid inverter 500vdc - 490k Sunmart Vmiii plus 3.5kw 24v 100a hybrid inverter 500vdc - 515k Sunmart Vmiii plus 5.5kw 48v 100a hybrid inverter 500vdc - (out of stock) Sorotec Revo Vmii 5.5kw 48v 100a hybrid inverter 500vdc - (out of stock) Sorotec Revo Vmii 3.5kw 24v 100a hybrid 5500w mppt inverter 500vdc - Sorotec 5.5kw 48v 100a hybrid 5500w mppt inverter 500vdc parallel version (includes parrallel kit) - 730k Sorotec 3.5kw 24v 100a hybrid 5500w mppt inverter 500vdc parallel version (includes parrallel kit)- 560k Sorotec Revo vmiii 5.5kw 48v 100a hybrid inverter 500vdc - out of stock Sorotec Revo vmiii 3.5kw 24v 100a hybrid inverter 500vdc - 560k Sorotec Revo vmiv 5.6kw 48v 120a hybrid inverter 500vdc (RGB LED LIGHTS) - out of stock Sorotec Revo vmiv pro 6kw 48v 120a hybrid inverter 500vdc RGB LED LIGHTS (dual outputs, smart load management) - 750k Powmr 3.2kva 24v 80a 450vdc mppt hybrid inverter - 370k Powmr 3.5kva 24v 100a 500vdc mppt hybrid inverter - 530k Powmr 5.5kva 48v 100a mppt hybrid inverter - 600k Snadi 3.5kva 24v inverter wall mount (transformer) - 430k Snadi 5.5kva 24v inverter wall mount (transformer) - 560k Snadi 5.5kva 48v inverter seewall mount (transformer) - 560k CHARGE CONTROLLER Epever triron 40a mppt charge controller - 170k Epever tracer 60a mppt charge controller - 285k Epever tracer 100a mppt charge controller - 420k Must 100a mppt solar charge controller - (out of stock) Must 60a mppt solar charge controller - 200k Must 80a mppt solar charge controller - (out of stock) Fangpusun flexmax 80a mppt charge controller - 440k Fangpusun flexmax 60a mppt charge controller - (out of stock) Fangpusun 50a 12/24v - 145k 40amps mppt lumiax Bluetooth controller(mobile app compatible)- out of stock 60amps lumiax Bluetooth mppt controller(Mobile app compatible) - out of stock 40amps sunfield mppt controller - 120k 80amps sunfield mppt charge controller - 220k 100amps sms mppt controller - 240k 60amps 12/24/36/48v powermr mppt new model - 140k Battery Cworth 5kwh 48v - 1.15m Greenpole 48v 100ah 5kwh lithium battery - 1.55m Deye 5kwh lithium battery - ?? Kartel 220ah tubular battery - 295k Starplus 220ah tubular battery - 285k Mpower 220ah tubular battery - ?? AVR Avr(under n over voltage regulator)/current limiter 60a - 13k Avr(under n over voltage regulator)/current limiter 60a (Tomzn) - 15k Avr (under n over voltage regulator)/current limiter 63a 4pole 3 Phase (tomzn) - 38k BREAKERS/SPDs Change over breaker/MTS - 7.5k Change over breaker/MTS 4pole - 18k DC SPD 500v - 13k DC SPD 500v (Tomzn) - 15k DC spd 1000v (tomzn)- 17k Ac spd 275v (worldsunlight )- 10k Ac spd 275v (tomzn) - 11.5k Ac spd 4 pole - 18k VOLTMETERS/ ENERGY METER DC Voltmeter (5v- 120v ) - 4.5k DC Voltmeter (8v- 100v / with battery indicator and %) - 8k (out of stock) DC Battery and energy Meter 200a - 25k 6 in 1 Ac Energy meter ( watts, voltage,kWh,amps, freq, power factor) - 28k Kill a Watt meter - 18k MC4 CONNECTORS Mc4 connectors - 1k Mc4 y connector 2 in 1 - 5k Mc4 y connector 3 in 1- 7k Mc4 y connector 4 in 1 - 13k PROGRAMMABLE TIMER Programmable timer 15a UK pkug - 13k Programmable timer 25a - 13k BREAKERS/ DC FUSE HOLDERS solar DC fuse holder 1 pole (tomzn) - 3.5k Solar DC fuse holder 2 pole (tomzn)- 6k Solar DC fuse (10a/16a/20a/25a/30a) - 2.5k DC breaker 10a 600v double pole (tomzn)- 8k DC breaker 16a 600v double pole (tomzn) - 8k DC breaker 20a 600v double pole (tomzn) - 8k DC breaker 25a 600v double pole (tomzn) - 8k DC breaker 125a double pole (tomzn) - 14k DC breaker 125a single pole (tomzn) - 8k DC breaker 100a double pole (tomzn) - 13k DC breaker single pole (32-63a) - 3.5k DC breakers double pole 63a - 7.5k DC breakers double pole 40a - 7.5k DC breaker double pole 100a - 12.5k Dc breaker double pole 125a - 13k 250a DC mccb breaker double pole (Tomzn) - 38k 250a DC mccb breaker double pole (CSQ) - 36k 125a DC mccb breaker double pole (CSQ) - 26k Ac breaker double pole 10a (Tomzn)- 5.5k Ac breaker double pole 16a (Tomzn)- 5.5k Ac breaker double pole 32a (Tomzn)- 5.5k Ac breaker double pole 63a (Tomzn)- 5.5k Ac breaker double pole 10a (Chint)- 6k Ac breaker double pole 16a (Chint)- 6k Ac breaker double pole 32a (Chint)- 6k Ac breaker double pole 63a (Chint)- 6k BATTERY EQUALIZER Ha02 battery balancer 48v - out of stock Ha02 battery equalizer 24v - out of stock AUTOMATIC TRANSFER SWITCH(ATS) Automatic transfer switch (ATS) 63a (tomzn) - ( out of stock) Automatic transfer switch (ATS) 100a (tomzn) - 38k Automatic transfer switch (ATS) 125a (tomzn) - out of stock Automatic transfer switch (ATS) 63a 2in2out wall mount (tomzn) - 43k Automatic transfer switch (ATS) 100a 4pole 3 phase (tomzn) - 60k ENCLOSURE BOX/ BUSBAR 4way breaker enclosure - 4k 6way breaker enclosure - 5k 8 way breaker enclosure - 6k 12 way breaker enclosure - 8k Busbar (Red and Black) imported - 37k Busbar +ve and -ve (local) - 22k DM for other items. Call/chat - 08 one 1739 829 four
|
HeavenlyBang(m): 4:14pm On Apr 24, 2024 |
EduTechTainMent: Would you recommend them? |
QuoteJust1nce: 4:54pm On Apr 24, 2024 |
bassdow: Oga, Starlink is not MTN or Airtel , the grandmasters of deception. Unlimited is unlimited, use 100TB if you can within 30 days; 500TB if you want, The worse case scenario; your speed might be throttled after hitting FUP. But guess what, Starlink doesn't throttle Nigerians yet and when they did in their country, speeds dropped to around 30Mbps. But dey browse dey go till you quench. They actually have a very detailed legal documentation page; but as a "lazy youth" that you are; i know you cannot find it. . Do your research, I will not help you. 2 Likes 1 Share |
Betnomore: 5:05pm On Apr 24, 2024 |
Bro abeg are u sure it is not capped? Airtel don show me wayo in the past with their deceptive ment. Abeg can you show me your data usage in a month where u used like 500gb. Cos i dey fear to go buy am now, make story come enter am again. Airtel too dey lie na why i dey skeptical. Me I no mind the speed cos e dey okay for wetin I need. Peterlove11: |
swagifted(m): 5:21pm On Apr 24, 2024 |
QuoteJust1nce:my grand setup would be High voltage sha ... But i gats build a separate building housing all the batteries and inverters... And all s would be on the ground...na only AC go leave the separate house enter the electrical in the main house. |
QuoteJust1nce: 5:33pm On Apr 24, 2024 |
bassdow: Baba this your explanation no enter oh, to be honest. Oya relax. They throttle because of FUP (fair usage policy). If they allow you to keep going at maximum speed forever; just you alone would rack up too much bills and most importantly; prevent others from enjoying the service and that's being fair. Your speed got reduced to say 30Mbps but you could still and without being cut off. So if you had enough time on your hands you go a petabyte. The only limiting factor at this point would be 30 calendar days; cos yo're gonna run out of time. If something is not unlimited, then it is capped e.g. 2TB cap. At the end of that cap; you can longer browse. It's simple. Or people like aitel would give you 5/10GB per day and no browsing until the next 24hrs. You see the difference? It's very clear. One stops you from browsing completely until you recharge or wait one full day. The other keeps going (possibly at reduced speeds) |
adrusa: 5:41pm On Apr 24, 2024 |
QuoteJust1nce: So, what is "priority data 40Gb" if Starlink is truly unlimited? https://www.starlink.com/legal/documents/DOC-1469-65206-75?regionCode=NG My fibre connecrion is truly unlimited in of data cap. I can do 100TB if I have the need and the time for it. No FUP at all. |
QuoteJust1nce: 5:44pm On Apr 24, 2024 |
adrusa: You should check their glossary. Priority is given to residential customers against roaming customers (mobile). If you need faster speeds while roaming; you need to enable Priority data. Or if you want to use it in the sea or while in motion; or globally. Attached a screenshot that explains it better.
|
Betnomore: 6:09pm On Apr 24, 2024 |
Till now i never get answer to my inquiry. No local seller around ikorodu? Betnomore: |
ojesymsym: 6:53pm On Apr 24, 2024 |
Person non fit use python achieve all these things? jonescosmos: 1 Like |
ojesymsym: 7:01pm On Apr 24, 2024 |
Both of you are saying the different things on same topic, so which is the correct one in of being more lethal? High voltage/low current or High current/ low voltage? QuoteJust1nce: bassdow: |
mank1234(m): 7:35pm On Apr 24, 2024 |
Parser:It's not a straight yes or no. In a short circuit situation, it depends on a lot of factors, including the power source,. Public utility will be catastrophic because the source can sustain the power surge associated with a short. But with solar in a single series connection, no catastrophy as only the rated current Isc will flow. If the is well made and the cabling is rightly sized, the energy can be dissipated indefinitely without any damage. In an accidental shocking (body touch) situation, higher voltage is more catastrophic.. |
mank1234(m): 7:45pm On Apr 24, 2024 |
mank1234: For battery, unlike a solar , a short circuit is catastrophic because the battery can supply the the entire short circuit current without limit (very low internal resistance). In HV battery, if the terminals is not grounded (physically or capacitively), no shock ensued without touching both terminals. |