NewStats: 3,264,975 , 8,185,243 topics. Date: Friday, 13 June 2025 at 01:34 AM 103i5u

6z3e3g

Solar Power For An Average Middle Class Household - Technology Market (20) - Nairaland 13196x

Solar Power For An Average Middle Class Household (46812 Views)

(4)

Go Down)

Tover: 1:09pm On Mar 07, 2024
Obnoxious2001:

1.5kva transformer based pure sine wave inverter definitely

Okay boss., thanks so much

1 Like

samistry(m): 7:40am On Mar 08, 2024
I asked a for market survey on connection that will power 2 rechargeable fans, a laptop and minor accessories.
Please is this amount correct?

Hero2t: 8:08am On Mar 08, 2024
samistry:
I asked a for market survey on connection that will power 2 rechargeable fans, a laptop and minor accessories.
Please is this amount correct?

Do you really want to spend that much to power the things you mentioned? If you go the DC route, you could save some cost. Buy a laptop power bank for around 200k or 330k, buy two 150W solar s to charge for less than 100k, and buy a solar charge controller for around 40k and you are good to go. You will need some wires for the connections and DC breakers. You can also add an inverter to it in the future if you want.

You can also buy only the power bank and charge with light too. The 330k is about 1230Wh.

1 Like

dollarnaira: 10:01am On Mar 08, 2024
samistry:
I asked a for market survey on connection that will power 2 rechargeable fans, a laptop and minor accessories.
Please is this amount correct?

grin grin grin grin
Extremely outrageous
WhatsApp 081 33 nine 3 2627
saysoo: 12:52pm On Mar 08, 2024
Guys please I need a quotation (cost)
for a complete solar components that can power a 2hp compressor off grid.
Obnoxious2001(m): 8:41am On Mar 09, 2024
samistry:
I asked a for market survey on connection that will power 2 rechargeable fans, a laptop and minor accessories.
Please is this amount correct?
What are the minor accessories?
This quote doesn't look minor. If it those rechargeable fan, laptop the smart solar kit is your best bet.
Obnoxious2001(m): 8:43am On Mar 09, 2024
saysoo:
Guys please I need a quotation (cost)
for a complete solar components that can power a 2hp compressor off grid.
How long do you want it running?
samistry(m): 9:23am On Mar 10, 2024
Minor accessories like phones. How much is it for solar kit?
Obnoxious2001:

What are the minor accessories?
This quote doesn't look minor. If it those rechargeable fan, laptop the smart solar kit is your best bet.

saysoo: 9:24am On Mar 10, 2024
Obnoxious2001:

How long do you want it running?
8 to 10 hours.
Obnoxious2001(m): 10:10am On Mar 10, 2024
saysoo:

8 to 10 hours.

When are you running it day or night
Obnoxious2001(m): 10:10am On Mar 10, 2024
samistry:
Minor accessories like phones. How much is it for solar kit?

You can get for as low as 150k the higher the back up the more it will cost
saysoo: 10:35am On Mar 12, 2024
Obnoxious2001:

When are you running it day or night
evening to morning 7pm to 5am.
Obnoxious2001(m): 9:59pm On Mar 12, 2024
saysoo:
evening to morning 7pm to 5am.
This should cost you around 5m roughly
saysoo: 3:19pm On Mar 14, 2024
Obnoxious2001:

This should cost you around 5m roughly
Wow, since it is buisness, i will go for Lister generator. Thanks
Obnoxious2001(m): 3:30pm On Mar 14, 2024
saysoo:
Wow, since it is buisness, i will go for Lister generator. Thanks
This will be cheaper for you on the long term if you are running an ice block business.

Besides your design requires more of battery backup.

Good luck on your quest sir smiley
Ournolly: 6:05pm On Mar 14, 2024
Obnoxious2001:

This should cost you around 5m roughly
I am curious on which battery can power 2 hp compressor for 10 hours of no sunlight.

That will be like 12 dry cell battery.
What's the evaluation on Lithium battery?
Eldemmi(m): 10:31am On Mar 17, 2024
Obnoxious2001:

This will be cheaper for you on the long term if you are running an ice block
Besides your design requires more of battery backup.

Good luck on your quest sir smiley

Will 5m do it and be effective
Please can you break down the requirements for me.
Obnoxious2001(m): 11:41am On Mar 17, 2024
Ournolly:

I am curious on which battery can power 2 hp compressor for 10 hours of no sunlight.

That will be like 12 dry cell battery.
What's the evaluation on Lithium battery?
Yes
15kwh
Obnoxious2001(m): 12:14pm On Mar 17, 2024
Eldemmi:


Will 5m do it and be effective
Please can you break down the requirements for me.
Sorry I just did review on it now.
5m can get the materials. Thought not completely
Eldemmi(m): 1:23pm On Mar 17, 2024
Obnoxious2001:

Sorry I just did review on it now.
5m can get the materials. Thought not completely

How much can do it then.
Thanks


Nteogwuija(m): 2:42pm On Mar 18, 2024
Guys, pls how do I prevent my set up from thunder? About 2 weeks ago, there was rainfall and it came with thunder strikes which affected my 1ka inverter, which is currently undergoing repair. I have bought DC surge protector and breaker. But I'm still feeling this might not be enough, cuz someone told me that I can have these accessories but if the house isn't earthed properly that they won't work.

Please what measures can I take to secure my setup from the effects of subsequent thunder strikes?

Thanks for your responses in advance.
b0rn2fuck(m): 2:17am On Mar 19, 2024
Obnoxious2001:

What are the minor accessories?
This quote doesn't look minor. If it those rechargeable fan, laptop the smart solar kit is your best bet.

Why is my solar drawing current back when the sun goes down, I decided not to put up loads for two days, I notice rhe current always regressing as soon as the sun become low
b0rn2fuck(m): 2:18am On Mar 19, 2024
Obnoxious2001:

Sorry I just did review on it now.
5m can get the materials. Thought not completely


Why is my solar drawing current back when the sun goes down, I decided not to put up loads for two days, I notice rhe current always regressing as soon as the sun become low.i think this my installer don't have full knowledge of what he was doing
Obnoxious2001(m): 11:25am On Mar 19, 2024
b0rn2fuck:
Why is my solar drawing current back when the sun goes down, I decided not to put up loads for two days, I notice rhe current always regressing as soon as the sun become low.i think this my installer don't have full knowledge of what he was doing

Draw current back?
The solar Na Drogba grin grin?

When you say draw back, is it not producing any current or your battery doesn't get charged?


When did you start noticing this
Obnoxious2001(m): 11:29am On Mar 19, 2024
[quote author=Eldemmi post=128968952][/quote]

10m should tidy the project.

Besides the initial op wanted the system to run at night.

If you plan to run during the day, 7m will cater for it
Obnoxious2001(m): 11:38am On Mar 19, 2024
Nteogwuija:
Guys, pls how do I prevent my set up from thunder? About 2 weeks ago, there was rainfall and it came with thunder strikes which affected my 1ka inverter, which is currently undergoing repair. I have bought DC surge protector and breaker. But I'm still feeling this might not be enough, cuz someone told me that I can have these accessories but if the house isn't earthed properly that they won't work.

Please what measures can I take to secure my setup from the effects of subsequent thunder strikes?

Thanks for your responses in advance.

Go and get an effective earth. Your earth resistance should read about 10-5 ohms for residential purpose and 0-5ohms for industrial applications.

But that aside, Recently I was thinking about this lightening strike.
And I came up with this hypothesis

I was thinking what if I include a AC SPD to the output of the inverter too( reason is most lightening strike are likely to come from the AC side.)

Meanwhile it's just an hypothesis undecided.
b0rn2fuck(m): 11:54am On Mar 19, 2024
Obnoxious2001:


Draw current back?
The solar Na Drogba grin grin?

When you say draw back, is it not producing any current or your battery doesn't get charged?


When did you start noticing this
anytime around 4 o'clock observed the current seems to be reversing . The solar is new
Nteogwuija(m): 12:29pm On Mar 19, 2024
Obnoxious2001:


Go and get an effective earth. Your earth resistance should read about 10-5 ohms for residential purpose and 0-5ohms for industrial applications.

But that aside, Recently I was thinking about this lightening strike.
And I came up with this hypothesis

I was thinking what if I include a AC SPD to the output of the inverter too( reason is most lightening strike are likely to come from the AC side.)

Meanwhile it's just an hypothesis undecided.


Thanks for the response. But is it possible to install earth in a rented apartment? And I also learnt that an effective earthing can be very expensive, reason why most landlords opt for the less effective ones.
Obnoxious2001(m): 1:04pm On Mar 19, 2024
Nteogwuija:


Thanks for the response. But is it possible to install earth in a rented apartment? And I also learnt that an effective earthing can be very expensive, reason why most landlords opt for the less effective ones.

Aside the cost, the Question is how many people have the test equipment to achieve a good Earthing.

I am just coming from where they sell test equipment, test equipment are expensive.

Earth megger 200k?
I was told 95k some months back and I felt it was expensive.

Yes you can install one in a rented apartment
Obnoxious2001(m): 1:05pm On Mar 19, 2024
b0rn2fuck:
anytime around 4 o'clock observed the current seems to be reversing . The solar is new
Do you have pictures of this occurrence?
Snap your cc when it's normal and when it's reversing let's see.

That reversing you are mentioning dey amaze me grin
Nteogwuija(m): 2:53pm On Mar 19, 2024
Obnoxious2001:


Go and get an effective earth. Your earth resistance should read about 10-5 ohms for residential purpose and 0-5ohms for industrial applications.

But that aside, Recently I was thinking about this lightening strike.
And I came up with this hypothesis

I was thinking what if I include a AC SPD to the output of the inverter too( reason is most lightening strike are likely to come from the AC side.)

Meanwhile it's just an hypothesis undecided.


I think the AC SPD should make sense because I was surprised how the lightening didn't affect the charge controller, because I felt it came from the solar. My thought now is that since the strike affected the inverter, it most likely came from the mains. So I think it makes sense to put an SPD between the mains and the inverter. This is just my layman thought process.
Obnoxious2001(m): 3:04pm On Mar 19, 2024
Nteogwuija:


I think the AC SPD should make sense because I was surprised how the lightening didn't affect the charge controller, because I felt it came from the solar. My thought now is that since the strike affected the inverter, it most likely came from the mains. So I think it makes sense to put an SPD between the mains and the inverter. This is just my layman thought process.

Yes one ought to be at the input side.

But am thinking of using another at the output as well.

This protection thing be like trial by error.

Reply)

Fantastic Deals On Generators, Air Conditioners & Others! Pics attached!

(Go Up)

Sections: How To . 35
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or s on Nairaland.